Onsite assistance to diagnose or correct problems
Problem:
Industrial
anti-pollution fans that work in high-stress
environments like power plants pose special problems
when their performance degrades or components fail,
because downtime is extremely expensive and the
scale of the necessary corrections can be very
large. SixD engineers have used several approaches
to diagnosing the causes of excessive vibration or
blade cracking in numerous 5,000-10,000 HP
industrial fans.
Solution: For this fan, SixD engineers
instrumented and conducted a performance test on a
fan-motor unit to measure strains and stresses
developing in the rotor. The hub and several
locations on the fronts and backs of two blades were
fitted with strain gages and a data acquisition
system capable of withstanding the high gs
was attached directly to the hub. A blade impact
test was also performed to document the unit’s
natural frequency.

Benefit:
Data from the
test guided design modifications to prevent costly
future downtime.
- Services:
Vibration troubleshooting
Data acquisition
|